Researchers compared deep-learning and expert measurements of left-ventricular ejection fraction in 27,382 consecutive cardiac MRI patients from the United Kingdom and United States. Over a median 5.6 years of follow-up, 3,458 patients died, allowing the team to test how strongly each measurement method was associated with all-cause mortality.

AI-derived ejection fraction was slightly but significantly more predictive of mortality than clinician measurements, including after adjustment for age and sex. The automated analysis took about two to three seconds per patient, versus roughly 13 minutes reported for expert analysis, suggesting a potential first-pass workflow advantage rather than a replacement for clinical interpretation.

The evidence is retrospective and prognostic; it does not show that using the tool improves treatment decisions or patient outcomes. Human oversight remains important: errors occurred in about 1% of patients, affecting 0.08% of images, and clinician measurements performed slightly better in the hypertrophic-cardiomyopathy subgroup.

Source record: Brightwire summarized and evaluated this development from the linked primary material. Read the original for complete context.

Read at The Lancet Digital Health