Researchers led by Argonne National Laboratory studied how trace iron moves through alkaline water electrolyzers, where small amounts can improve nickel-electrode performance but can also form metallic deposits. The team tracked iron across electrodes, electrolyte and porous separators in test cells operating for as long as 1,000 hours.
Iron-rich dendrites formed on cathodes and intruded into the separator’s near surface, but the researchers found no evidence that they crossed the separator during the 1,000-hour tests. The study identified five governing factors: iron accumulation, electrolyte flow rate, electrode smoothness, cathode potential and electrode atomic structure.
The result is a mechanism and control map, not a finished commercial durability improvement. Argonne says the work, published in Joule with national-laboratory, university and industry collaborators, gives developers a basis for retaining iron’s efficiency benefit while testing how to suppress deposits under more demanding operating conditions.
Source record: Brightwire summarized and evaluated this development from the linked primary material. Read the original for complete context.
Read at Argonne National Laboratory