Researchers tested a hybrid photovoltaic cooling system that pairs a water-soaked cellulose pad behind a panel with short water sprays on the front surface when module temperature exceeds 45°C. A 35-watt fan draws air through the rear pad and delivers the resulting cooled air for ventilation.
Two identical 150-watt modules were compared on a Baghdad rooftop during clear-day tests from July through mid-September. Rear cooling alone lowered module temperature by about 20°C; adding the front spray produced a maximum reduction of 29.7°C and increased electrical efficiency by up to 26% relative to the uncooled panel.
The outlet air reached roughly 30°C to 33°C at about 62% relative humidity, so the authors frame it as useful precooling rather than stand-alone indoor comfort. Future optimization must also weigh water use, pump and fan energy, maintenance and performance at larger scale.
Source record: Brightwire summarized and evaluated this development from the linked primary material. Read the original for complete context.
Read at pv magazine