Argonne researchers used a 59-foot experimental loop, roughly half the height of a commercial reactor system, to test a reactor-cavity cooling concept under controlled conditions. The apparatus let the team vary both the heat entering the system and the height of the inlet from its water tank.
At a full-scale equivalent of 2.4 megawatts, flashing steam reached the chimney in about 20 minutes; at 1.75 megawatts it took about 90 minutes, and at 1.4 megawatts it did not occur during the test. Those measurements establish practical thresholds for when boiling begins to disrupt otherwise stable natural circulation.
Inlet placement mattered as well. A mid-level inlet produced boiling and flashing sooner but delivered steadier flow in some scenarios, while a lower inlet experienced flashing-driven instability. The results give reactor designers and regulators experimental data for balancing rapid heat removal against stable long-duration operation.
Source record: Brightwire summarized and evaluated this development from the linked primary material. Read the original for complete context.
Read at Argonne National Laboratory